Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.447
Filtrar
1.
Adv Sci (Weinh) ; 11(16): e2308277, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38380504

RESUMO

This paper presents an acoustic transducer for fully implantable cochlear implants (FICIs), which can be implanted on the hearing chain to detect and filter the ambient sound in eight frequency bands between 250 and 6000 Hz. The transducer dimensions are conventional surgery compatible. The structure is formed with 3  × 3 × 0.36 mm active space for each layer and 5.2 mg total active mass excluding packaging. Characterization of the transducer is carried on an artificial membrane whose vibration characteristic is similar to the umbo vibration. On the artificial membrane, piezoelectric transducer generates up to 320.3 mVpp under 100 dB sound pressure level (SPL) excitation and covers the audible acoustic frequency. The measured signal-to-noise-ratio (SNR) of the channels is up to 84.2 dB. Sound quality of the transducer for fully implantable cochlear implant application is graded with an objective qualification method (PESQ) for the first time in the literature to the best of the knowledge, and scored 3.42/4.5.


Assuntos
Implantes Cocleares , Transdutores , Vibração , Humanos , Desenho de Equipamento , Razão Sinal-Ruído , Acústica/instrumentação , Ossículos da Orelha/cirurgia , Desenho de Prótese/métodos
2.
Sensors (Basel) ; 23(9)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37177769

RESUMO

The sound amplification ratios of sealed air chambers with different shapes were quantitatively compared to design a body-conduction microphone to measure animal scratching sounds. Recently, quantitative monitoring of scratching intensity in dogs has been required. We have already developed a collar with a body-conduction microphone to measure body-conducted scratching sounds. However, the air chamber, one of the components of the body-conduction microphone, has not been appropriately designed. This study compared the amplification ratios of air chambers with different shapes through numerical analysis and experiments. According to the results, the horn-shaped air chamber achieved the highest amplification performance, at least for sound frequencies below 3 kHz. The simulated amplification ratio of the horn-shaped air chamber with a 1 mm height and a 15 mm diameter was 52.5 dB. The deformation of the bottom of the air chamber affected the amplification ratio. Adjusting the margin of the margined horn shape could maintain its amplification ratio at any pressing force. The simulated and experimental amplification ratios of the margined horn-shaped air chamber were 53.4 dB and 19.4 dB, respectively.


Assuntos
Acústica , Som , Animais , Cães , Acústica/instrumentação
3.
Nat Commun ; 13(1): 987, 2022 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-35190549

RESUMO

Manipulation of micro/nano particles has been well studied and demonstrated by optical, electromagnetic, and acoustic approaches, or their combinations. Manipulation of internal structure of droplet/particle is rarely explored and remains challenging due to its complicated nature. Here we demonstrated the manipulation of internal structure of disk-in-sphere endoskeletal droplets using acoustic wave. We developed a model to investigate the physical mechanisms behind this interesting phenomenon. Theoretical analysis of the acoustic interactions indicated that these assembly dynamics arise from a balance of the primary and secondary radiation forces. Additionally, the disk orientation was found to change with acoustic driving frequency, which allowed on-demand, reversible adjustment of the disk orientations with respect to the substrate. This dynamic behavior leads to unique reversible arrangements of the endoskeletal droplets and their internal architecture, which may provide an avenue for directed assembly of novel hierarchical colloidal architectures and intracellular organelles or intra-organoid structures.


Assuntos
Acústica/instrumentação , Som
4.
PLoS One ; 17(1): e0262240, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35045111

RESUMO

An automatic non-contact cough detector designed especially for night audio recordings that can distinguish coughs from snores and other sounds is presented. Two different classifiers were implemented and tested: a Gaussian Mixture Model (GMM) and a Deep Neural Network (DNN). The detected coughs were analyzed and compared in different sleep stages and in terms of severity of Obstructive Sleep Apnea (OSA), along with age, Body Mass Index (BMI), and gender. The database was composed of nocturnal audio signals from 89 subjects recorded during a polysomnography study. The DNN-based system outperformed the GMM-based system, at 99.8% accuracy, with a sensitivity and specificity of 86.1% and 99.9%, respectively (Positive Predictive Value (PPV) of 78.4%). Cough events were significantly more frequent during wakefulness than in the sleep stages (p < 0.0001) and were significantly less frequent during deep sleep than in other sleep stages (p < 0.0001). A positive correlation was found between BMI and the number of nocturnal coughs (R = 0.232, p < 0.05), and between the number of nocturnal coughs and OSA severity in men (R = 0.278, p < 0.05). This non-contact cough detection system may thus be implemented to track the progression of respiratory illnesses and test reactions to different medications even at night when a contact sensor is uncomfortable or infeasible.


Assuntos
Acústica/instrumentação , Índice de Massa Corporal , Tosse/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Fases do Sono , Amplificadores Eletrônicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Valor Preditivo dos Testes
5.
PLoS One ; 16(12): e0261040, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34914761

RESUMO

Corrosion in carbon-steel pipelines leads to failure, which is a major cause of breakdown maintenance in the oil and gas industries. The acoustic emission (AE) signal is a reliable method for corrosion detection and classification in the modern Structural Health Monitoring (SHM) system. The efficiency of this system in detection and classification mainly depends on the suitable AE features. Therefore, many feature extraction and classification methods have been developed for corrosion detection and severity assessment. However, the extraction of appropriate AE features and classification of various levels of corrosion utilizing these extracted features are still challenging issues. To overcome these issues, this article proposes a hybrid machine learning approach that combines Wavelet Packet Transform (WPT) integrated with Fast Fourier Transform (FFT) for multiresolution feature extraction and Linear Support Vector Classifier (L-SVC) for predicting corrosion severity levels. A Laboratory-based Linear Polarization Resistance (LPR) test was performed on carbon-steel samples for AE data acquisition over a different time span. AE signals were collected at a high sampling rate with a sound well AE sensor using AEWin software. Simulation results show a linear relationship between the proposed approach-based extracted AE features and the corrosion process. For multi-class problems, three corrosion severity stages have been made based on the corrosion rate over time and AE activity. The ANOVA test results indicate the significance within and between the feature-groups where F-values (F-value>1) rejects the null hypothesis and P-values (P-value<0.05) are less than the significance level. The utilized L-SVC classifier achieves higher prediction accuracy of 99.0% than the accuracy of other benchmarked classifiers. Findings of our proposed machine learning approach confirm that it can be effectively utilized for corrosion detection and severity assessment in SHM applications.


Assuntos
Acústica/instrumentação , Algoritmos , Aprendizado de Máquina , Modelos Estatísticos , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte , Análise de Ondaletas , Corrosão , Análise de Fourier
6.
Commun Biol ; 4(1): 1275, 2021 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-34759372

RESUMO

Microphone arrays are an essential tool in the field of bioacoustics as they provide a non-intrusive way to study animal vocalizations and monitor their movement and behavior. Microphone arrays can be used for passive localization and tracking of sound sources while analyzing beamforming or spatial filtering of the emitted sound. Studying free roaming animals usually requires setting up equipment over large areas and attaching a tracking device to the animal which may alter their behavior. However, monitoring vocalizing animals through arrays of microphones, spatially distributed over their habitat has the advantage that unrestricted/unmanipulated animals can be observed. Important insights have been achieved through the use of microphone arrays, such as the convergent acoustic field of view in echolocating bats or context-dependent functions of avian duets. Here we show the development and application of large flexible microphone arrays that can be used to localize and track any vocalizing animal and study their bio-acoustic behavior. In a first experiment with hunting pallid bats the acoustic data acquired from a dense array with 64 microphones revealed details of the bats' echolocation beam in previously unseen resolution. We also demonstrate the flexibility of the proposed microphone array system in a second experiment, where we used a different array architecture allowing to simultaneously localize several species of vocalizing songbirds in a radius of 75 m. Our technology makes it possible to do longer measurement campaigns over larger areas studying changing habitats and providing new insights for habitat conservation. The flexible nature of the technology also makes it possible to create dense microphone arrays that can enhance our understanding in various fields of bioacoustics and can help to tackle the analytics of complex behaviors of vocalizing animals.


Assuntos
Acústica/instrumentação , Comunicação Animal , Aves , Quirópteros , Ecolocação , Ecologia/instrumentação , Etologia/instrumentação , Animais , Idaho
7.
PLoS One ; 16(10): e0258842, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34665827

RESUMO

In recent years, noisy bustling environments have created situations in which earmuffs must soundproof only specific noise while transmitting significant sounds, such as voices, for work safety and efficiency. Two sound insulation technologies have been utilized: passive noise control (PNC) and active noise control (ANC). However, PNC is incapable of insulating selective frequencies of noise, and ANC is limited to low-frequency sounds. Thus, it has been difficult for traditional earmuffs to cancel out only high-frequency noise that people feel uncomfortable hearing. Here, we propose an acoustic notch filtering earmuff utilizing Helmholtz resonator (HR) arrays that provides a sound attenuation effect around the tuneable resonant frequency. A sheet-like sound insulating plate comprising HR arrays is realized in a honeycomb structure. Since the resonant frequency is determined by the geometry of the HR arrays, a highly audible sound region can be designed as the target frequency. In this research, the acoustic notch filtering performance of the proposed HR array plate is investigated in both simulations and experiments. Furthermore, the fabricated earmuffs using the novel HR array plates achieve a sound insulation performance exceeding 40 dB at the target frequency, which is sufficiently high compared to that of conventional earmuffs. The experimental results confirm that the proposed device is a useful approach for insulating frequency-selective sound.


Assuntos
Acústica/instrumentação , Dispositivos de Proteção das Orelhas , Ruído/prevenção & controle , Desenho de Equipamento , Humanos
8.
PLoS One ; 16(9): e0257761, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34555110

RESUMO

Integrating Multibeam Echosounder (MBES) data (bathymetry and backscatter) and underwater video technology allows scientists to study marine habitats. However, use of such data in modeling suitable seagrass habitats in Malaysian coastal waters is still limited. This study tested multiple spatial resolutions (1 and 50 m) and analysis window sizes (3 × 3, 9 × 9, and 21 × 21 cells) probably suitable for seagrass-habitat relationships in Redang Marine Park, Terengganu, Malaysia. A maximum entropy algorithm was applied, using 12 bathymetric and backscatter predictors to develop a total of 6 seagrass habitat suitability models. The results indicated that both fine and coarse spatial resolution datasets could produce models with high accuracy (>90%). However, the models derived from the coarser resolution dataset displayed inconsistent habitat suitability maps for different analysis window sizes. In contrast, habitat models derived from the fine resolution dataset exhibited similar habitat distribution patterns for three different analysis window sizes. Bathymetry was found to be the most influential predictor in all the models. The backscatter predictors, such as angular range analysis inversion parameters (characterization and grain size), gray-level co-occurrence texture predictors, and backscatter intensity levels, were more important for coarse resolution models. Areas of highest habitat suitability for seagrass were predicted to be in shallower (<20 m) waters and scattered between fringing reefs (east to south). Some fragmented, highly suitable habitats were also identified in the shallower (<20 m) areas in the northwest of the prediction models and scattered between fringing reefs. This study highlighted the importance of investigating the suitable spatial resolution and analysis window size of predictors from MBES for modeling suitable seagrass habitats. The findings provide important insight on the use of remote acoustic sonar data to study and map seagrass distribution in Malaysia coastal water.


Assuntos
Acústica/instrumentação , Organismos Aquáticos/crescimento & desenvolvimento , Conservação dos Recursos Naturais/métodos , Magnoliopsida/crescimento & desenvolvimento , Algoritmos , Ecossistema , Entropia , Malásia , Modelos Biológicos , Análise Espacial
9.
Sci Rep ; 11(1): 14941, 2021 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-34294780

RESUMO

In situ observations of pelagic fish and zooplankton with optical instruments usually rely on external light sources. However, artificial light may attract or repulse marine organisms, which results in biased measurements. It is often assumed that most pelagic organisms do not perceive the red part of the visible spectrum and that red light can be used for underwater optical measurements of biological processes. Using hull-mounted echosounders above an acoustic probe or a baited video camera, each equipped with light sources of different colours (white, blue and red), we demonstrate that pelagic organisms in Arctic and temperate regions strongly avoid artificial light, including visible red light (575-700 nm), from instruments lowered in the water column. The density of organisms decreased by up to 99% when exposed to artificial light and the distance of avoidance varied from 23 to 94 m from the light source, depending on colours, irradiance levels and, possibly, species communities. We conclude that observations from optical and acoustic instruments, including baited cameras, using light sources with broad spectral composition in the 400-700 nm wavelengths do not capture the real state of the ecosystem and that they cannot be used alone for reliable abundance estimates or behavioural studies.


Assuntos
Peixes/fisiologia , Luz/efeitos adversos , Zooplâncton/fisiologia , Acústica/instrumentação , Animais , Organismos Aquáticos/fisiologia , Comportamento Animal/fisiologia , Conservação dos Recursos Naturais/métodos , Dispositivos Ópticos/efeitos adversos , Gravação em Vídeo/instrumentação
10.
Proc Natl Acad Sci U S A ; 118(30)2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-34282013

RESUMO

Seismic surveys are used to locate oil and gas reserves below the seabed and can be a major source of noise in marine environments. Their effects on commercial fisheries are a subject of debate, with experimental studies often producing results that are difficult to interpret. We overcame these issues in a large-scale experiment that quantified the impacts of exposure to a commercial seismic source on an assemblage of tropical demersal fishes targeted by commercial fisheries on the North West Shelf of Western Australia. We show that there were no short-term (days) or long-term (months) effects of exposure on the composition, abundance, size structure, behavior, or movement of this fauna. These multiple lines of evidence suggest that seismic surveys have little impact on demersal fishes in this environment.


Assuntos
Acústica/instrumentação , Ecossistema , Pesqueiros/estatística & dados numéricos , Peixes/crescimento & desenvolvimento , Dinâmica Populacional , Animais , Monitoramento Ambiental , Tecnologia de Sensoriamento Remoto , Austrália Ocidental
11.
Sci Rep ; 11(1): 11600, 2021 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-34078943

RESUMO

Sexual signals are archetypes of contingent evolution: hyper-diverse across species, often evolving fast and in unpredictable directions. It is unclear to which extent their evolutionary unpredictability weakens deterministic evolution, or takes place bounded by deterministic patterns of trait evolution. We compared the evolution of sound frequency in sexual signals (advertisement songs) and non-sexual social signals (calls) across > 500 genera of the crown songbird families. Contrary to the acoustic adaptation hypothesis, we found no evidence that forest species used lower sound frequencies in songs or calls. Consistent with contingent evolution in song, we found lower phylogenetic signal for the sound frequency of songs than calls, which suggests faster and less predictable evolution, and found unpredictable direction of evolution in lineages with longer songs, which presumably experience stronger sexual selection on song. Nonetheless, the most important deterministic pattern of sound frequency evolution-its negative association with body size-was stronger in songs than calls. This can be explained by songs being longer-range signals than most calls, and thus using sound frequencies that animals of a given size produce best at high amplitude. Results indicate that sexual selection can increase aspects of evolutionary contingency while strengthening, rather than weakening, deterministic patterns of evolution.


Assuntos
Adaptação Fisiológica , Evolução Biológica , Aves Canoras/fisiologia , Vocalização Animal/fisiologia , Acústica/instrumentação , Animais , Tamanho Corporal , Feminino , Masculino , Filogenia , Aves Canoras/classificação , Som
12.
Sci Rep ; 11(1): 10042, 2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33976350

RESUMO

Recognition and classification of mosquitoes is a critical component of vector-borne disease management. Vector surveillance, based on wingbeat frequency and other parameters, is becoming increasingly important in the development of automated identification systems, but inconsistent data quality and results frequently emerge from different techniques and data processing methods which have not been standardized on wingbeat collection of numerous species. We developed a simple method to detect and record mosquito wingbeat by multi-dimensional optical sensors and collected 21,825 wingbeat files from 29 North American mosquito species. In pairwise comparisons, wingbeat frequency of twenty six species overlapped with at least one other species. No significant differences were observed in wingbeat frequencies between and within individuals of Culex quinquefasciatus over time. This work demonstrates the potential utility of quantifying mosquito wingbeat frequency by infrared light sensors as a component of an automated mosquito identification system. Due to species overlap, wingbeat frequency will need to integrate with other parameters to accurately delineate species in support of efficient mosquito surveillance, an important component of disease intervention.


Assuntos
Acústica/instrumentação , Culicidae/classificação , Voo Animal , Asas de Animais/fisiologia , Animais , Culicidae/fisiologia , Feminino , Raios Infravermelhos , Dispositivos Ópticos
13.
J Acoust Soc Am ; 149(3): 1796, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33765803

RESUMO

While studies of urban acoustics are typically restricted to the audio range, anthropogenic activity also generates infrasound (<20 Hz, roughly at the lower end of the range of human hearing). Shutdowns related to the COVID-19 pandemic unintentionally created ideal conditions for the study of urban infrasound and low frequency audio (20-500 Hz), as closures reduced human-generated ambient noise, while natural signals remained relatively unaffected. An array of infrasound sensors deployed in Las Vegas, NV, provides data for a case study in monitoring human activity during the pandemic through urban acoustics. The array records a sharp decline in acoustic power following the temporary shutdown of businesses deemed nonessential by the state of Nevada. This decline varies spatially across the array, with stations close to McCarran International Airport generally recording the greatest declines in acoustic power. Further, declines in acoustic power fluctuate with the time of day. As only signals associated with anthropogenic activity are expected to decline, this gives a rough indication of periodicities in urban acoustics throughout Las Vegas. The results of this study reflect the city's response to the pandemic and suggest spatiotemporal trends in acoustics outside of shutdowns.


Assuntos
Acústica/instrumentação , COVID-19/prevenção & controle , Monitoramento Ambiental , Atividades Humanas , Cidades , Controle de Doenças Transmissíveis , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Humanos , Nevada , Ruído , Pandemias , SARS-CoV-2
14.
Commun Biol ; 4(1): 319, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33750897

RESUMO

Heart rhythm assessment is indispensable in diagnosis and management of many cardiac conditions and to study heart rate variability in healthy individuals. We present a proof-of-concept system for acquiring individual heart beats using smart speakers in a fully contact-free manner. Our algorithms transform the smart speaker into a short-range active sonar system and measure heart rate and inter-beat intervals (R-R intervals) for both regular and irregular rhythms. The smart speaker emits inaudible 18-22 kHz sound and receives echoes reflected from the human body that encode sub-mm displacements due to heart beats. We conducted a clinical study with both healthy participants and hospitalized cardiac patients with diverse structural and arrhythmic cardiac abnormalities including atrial fibrillation, flutter and congestive heart failure. Compared to electrocardiogram (ECG) data, our system computed R-R intervals for healthy participants with a median error of 28 ms over 12,280 heart beats and a correlation coefficient of 0.929. For hospitalized cardiac patients, the median error was 30 ms over 5639 heart beats with a correlation coefficient of 0.901. The increasing adoption of smart speakers in hospitals and homes may provide a means to realize the potential of our non-contact cardiac rhythm monitoring system for monitoring of contagious or quarantined patients, skin sensitive patients and in telemedicine settings.


Assuntos
Acústica/instrumentação , Arritmias Cardíacas/diagnóstico , Insuficiência Cardíaca/diagnóstico , Frequência Cardíaca , Telemedicina/instrumentação , Transdutores , Tecnologia sem Fio/instrumentação , Idoso , Algoritmos , Arritmias Cardíacas/fisiopatologia , Estudos de Casos e Controles , Eletrocardiografia , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/fisiopatologia , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Estudos Prospectivos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Fatores de Tempo
15.
J Vis Exp ; (167)2021 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-33554963

RESUMO

Efficient intracellular delivery of biomolecules is required for a broad range of biomedical research and cell-based therapeutic applications. Ultrasound-mediated sonoporation is an emerging technique for rapid intracellular delivery of biomolecules. Sonoporation occurs when cavitation of gas-filled microbubbles forms transient pores in nearby cell membranes, which enables rapid uptake of biomolecules from the surrounding fluid. Current techniques for in vitro sonoporation of cells in suspension are limited by slow throughput, variability in the ultrasound exposure conditions for each cell, and high cost. To address these limitations, a low-cost acoustofluidic device has been developed which integrates an ultrasound transducer in a PDMS-based fluidic device to induce consistent sonoporation of cells as they flow through the channels in combination with ultrasound contrast agents. The device is fabricated using standard photolithography techniques to produce the PDMS-based fluidic chip. An ultrasound piezo disk transducer is attached to the device and driven by a microcontroller. The assembly can be integrated inside a 3D-printed case for added protection. Cells and microbubbles are pushed through the device using a syringe pump or a peristaltic pump connected to PVC tubing. Enhanced delivery of biomolecules to human T cells and lung cancer cells is demonstrated with this acoustofluidic system. Compared to bulk treatment approaches, this acoustofluidic system increases throughput and reduces variability, which can improve cell processing methods for biomedical research applications and manufacturing of cell-based therapeutics.


Assuntos
Acústica/instrumentação , Células/metabolismo , Fluoresceína/metabolismo , Trealose/metabolismo , Células A549 , Células Cultivadas , Meios de Contraste/química , Humanos , Microbolhas , Linfócitos T/citologia , Ultrassom
16.
J Acoust Soc Am ; 149(1): 66, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514153

RESUMO

During the COVID-19 outbreak, the auscultation of heart and lung sounds has played an important role in the comprehensive diagnosis and real-time monitoring of confirmed cases. With clinicians wearing protective clothing in isolation wards, a potato chip tube stethoscope, which is a secure and flexible substitute for a conventional stethoscope, has been used by Chinese medical workers in the first-line treatment of COVID-19. In this study, an optimal design for this simple cylindrical stethoscope is proposed based on the fundamental theory of acoustic waveguides. Analyses of the cutoff frequency, sound power transmission coefficient, and sound wave propagation in the uniform lossless tube provide theoretical guidance for selecting the geometric parameters for this simple cylindrical stethoscope. A basic investigation into the auscultatory performances of the original tube and the optimal tube with proposed dimensions was conducted both in a semi-anechoic chamber and in a quiet laboratory. Both experimental results and front-line doctors' clinical feedback endorse the proposed theoretical optimization.


Assuntos
Acústica , Auscultação/normas , COVID-19/diagnóstico , Desenho de Equipamento/normas , Estetoscópios/normas , Acústica/instrumentação , Auscultação/instrumentação , Auscultação/métodos , COVID-19/epidemiologia , COVID-19/fisiopatologia , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Humanos , Sons Respiratórios/fisiologia , Sons Respiratórios/fisiopatologia
17.
Sensors (Basel) ; 21(2)2021 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-33445501

RESUMO

This research paper is concentrated on the design of biologically compatible lead-free piezoelectric composites which may eventually replace traditional lead zirconium titanate (PZT) in micromechanical fluidics, the predominantly used ferroelectric material today. Thus, a lead-free barium-calcium zirconate titanate (BCZT) composite was synthesized, its crystalline structure and size, surface morphology, chemical, and piezoelectric properties were analyzed, together with the investigations done in variation of composite thin film thickness and its effect on the element properties. Four elements with different thicknesses of BCZT layers were fabricated and investigated in order to design a functional acoustophoresis micromechanical fluidic element, based on bulk acoustic generation for particle control technologies. Main methods used in this research were as follows: FTIR and XRD for evaluation of chemical and phase composition; SEM-for surface morphology; wettability measurements were used for surface free energy evaluation; a laser triangular sensing system-for evaluation of piezoelectric properties. XRD results allowed calculating the average crystallite size, which was 65.68 Å3 confirming the formation of BCZT nanoparticles. SEM micrographs results showed that BCZT thin films have some porosities on the surface with grain size ranging from 0.2 to 7.2 µm. Measurements of wettability showed that thin film surfaces are partially wetting and hydrophilic, with high degree of wettability and strong solid/liquid interactions for liquids. The critical surface tension was calculated in the range from 20.05 to 27.20 mN/m. Finally, investigations of piezoelectric properties showed significant results of lead-free piezoelectric composite, i.e., under 5 N force impulse thin films generated from 76 mV up to 782 mV voltages. Moreover, an experimental analysis showed that a designed lead-free BCZT element creates bulk acoustic waves and allows manipulating bio particles in this fluidic system.


Assuntos
Acústica/instrumentação , Materiais Biocompatíveis/química , Cerâmica/química , Zircônio/química , Bário/química , Eletroforese/métodos , Desenho de Equipamento , Glicerol/química , Chumbo , Microscopia Eletrônica de Varredura , Azeite de Oliva/química , Espectrometria por Raios X , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X
18.
Sci Rep ; 11(1): 806, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33436710

RESUMO

Since 2001, hundreds of thousands of hours of underwater acoustic recordings have been made throughout the Southern Ocean south of 60° S. Detailed analysis of the occurrence of marine mammal sounds in these circumpolar recordings could provide novel insights into their ecology, but manual inspection of the entirety of all recordings would be prohibitively time consuming and expensive. Automated signal processing methods have now developed to the point that they can be applied to these data in a cost-effective manner. However training and evaluating the efficacy of these automated signal processing methods still requires a representative annotated library of sounds to identify the true presence and absence of different sound types. This work presents such a library of annotated recordings for the purpose of training and evaluating automated detectors of Antarctic blue and fin whale calls. Creation of the library has focused on the annotation of a representative sample of recordings to ensure that automated algorithms can be developed and tested across a broad range of instruments, locations, environmental conditions, and years. To demonstrate the utility of the library, we characterise the performance of two automated detection algorithms that have been commonly used to detect stereotyped calls of blue and fin whales. The availability of this library will facilitate development of improved detectors for the acoustic presence of Southern Ocean blue and fin whales. It can also be expanded upon to facilitate standardization of subsequent analysis of spatiotemporal trends in call-density of these circumpolar species.


Assuntos
Acústica/instrumentação , Balaenoptera/fisiologia , Processamento de Sinais Assistido por Computador/instrumentação , Espectrografia do Som/instrumentação , Vocalização Animal/fisiologia , Acesso à Informação , Animais , Regiões Antárticas , Conjuntos de Dados como Assunto , Espectrografia do Som/métodos , Especificidade da Espécie
19.
Artigo em Inglês | MEDLINE | ID: mdl-33481121

RESUMO

We developed a sound discrimination device to identify and localize the species of nocturnal animals in their natural habitat. The sound discrimination device is equipped with a microphone, a light-emitting diode, and a band-pass filter. By tuning the center frequency of the filter to include a dominant frequency of the calls of a focal species, we enable the device to be illuminated only when detecting the calls of the focal species. In experiments in a laboratory room, we tuned the sound discrimination devices to detect the calls of Hyla japonica or Rhacophorus schlegelii and broadcast the frog calls from loudspeakers. By analyzing the illumination pattern of the devices, we successfully identified and localized the two kinds of sound sources. Next, we placed the sound discrimination devices in a field site where actual male frogs (H. japonica and R. schlegelii) produced sounds. The analysis of the illumination pattern demonstrates the efficacy of the developed devices in a natural environment and also enables us to extract pairs of male frogs that significantly overlapped or alternated their calls.


Assuntos
Acústica/instrumentação , Anuros/fisiologia , Percepção Auditiva/fisiologia , Comportamento Animal/fisiologia , Gravação em Vídeo/instrumentação , Vocalização Animal/fisiologia , Animais , Masculino , Técnicas Fotoacústicas , Som , Especificidade da Espécie , Gravação em Vídeo/métodos
20.
J Acoust Soc Am ; 148(6): 3385, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33379875

RESUMO

Forced expiratory (FE) noise is a powerful bioacoustic signal containing information on human lung biomechanics. FE noise is attributed to a broadband part and narrowband components-forced expiratory wheezes (FEWs). FE respiratory noise is composed by acoustic and hydrodynamic mechanisms. An origin of the most powerful mid-frequency FEWs (400-600 Hz) is associated with the 0th-3rd levels of bronchial tree in terms of Weibel [(2009). Swiss Med. Wkly. 139(27-28), 375-386], whereas high-frequency FEWs (above 600 Hz) are attributed to the 2nd-6th levels of bronchial tree. The laboratory prototype of the apparatus is developed, which includes the electret microphone sensor with stethoscope head, a laptop with external sound card, and specially developed software. An analysis of signals by the new method, including FE time in the range from 200 to 2000 Hz and band-pass durations and energies in the 200-Hz bands evaluation, is applied instead of FEWs direct measures. It is demonstrated experimentally that developed FE acoustic parameters correspond to basic indices of lung function evaluated by spirometry and body plethysmography and may be even more sensitive to some respiratory deviations. According to preliminary experimental results, the developed technique may be considered as a promising instrument for acoustic monitoring human lung function in extreme conditions, including diving and space flights. The developed technique eliminates the contact of the sensor with the human oral cavity, which is characteristic for spirometry and body plethysmography. It reduces the risk of respiratory cross-contamination, especially during outpatient and field examinations, and may be especially relevant in the context of the COVID-19 pandemic.


Assuntos
Acústica/instrumentação , COVID-19 , Expiração/fisiologia , Sons Respiratórios/diagnóstico , Humanos , Ruído , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...